Comparison of force decay pattern in orthodontic elastomeric chains and NiTi closed coil springs, affected by five different mouthwashes: An in vitro Study

Dentistry 3000

View Publication Info
 
 
Field Value
 
Title Comparison of force decay pattern in orthodontic elastomeric chains and NiTi closed coil springs, affected by five different mouthwashes: An in vitro Study
 
Creator Mirhashemi, Amir Hossein
Habibi Khameneh, Niloofar
Shahpoorzadeh, Keyvan
Saffar Shahroudi, Atefe
 
Subject
Force reduction; orthodontics; mouthwash; elastomeric chain; closed coil springs
 
Description Background: The aim of this study was to compare the force decay pattern of elastomeric chains and NiTi coil springs which were exposed to five different commercially available mouthwashes.Methods: In this in vitro study, 60 pieces of elastomeric chain (EC) and 60 NiTi closed coil springs (CS) were divided into 6 groups. The specimens were exposed to one of these mouthwashes twice a day for 60 seconds:  Listerine, chlorhexidine, Orthokin, Persica, fluoride and artificial saliva as the control group. The elastomeric chains and NiTi springs were stretched so that they exert the initial force of 250 gr. Their force was measured on the 1, 7, 14 and 28 following days by means of a digital gauge.Results: Elastomeric chains and coil springs had force decrease over time, but EC' force reduction was greater with the highest reduction rate in the first week. However, in the CS group, the force decrease wasn't statistically significant in the first two weeks.  After 28 days in the control groups, 49.8% of the initial force was remained in ECs while the value was 93.3% for CSs. In comparison between mouthwashes, in EC groups, in all mouthwashes except Persica, the remained force was statistically less than control group.Conclusion: Force degradation of elastomeric chains could be exacerbated by use of mouthwashes. About coil springs, force decay was also observed. However, it was not statistically significant. Force reduction was detectable after four weeks of coil springs usage, but in EC groups, the greatest reduction was after the first week.  
 
Publisher University Library System, University of Pittsburgh
 
Contributor Tehran University of Medical Sciences
 
Date 2021-10-28
 
Type info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion


 
Format application/pdf
 
Identifier http://dentistry3000.pitt.edu/ojs/index.php/dentistry3000/article/view/158
10.5195/d3000.2021.158
 
Source Dentistry 3000; Vol 9, No 1 (2021); 95-106
2167-8677
 
Language eng
 
Relation http://dentistry3000.pitt.edu/ojs/index.php/dentistry3000/article/view/158/115
 
Rights Copyright (c) 2021 Amir Hossein Mirhashemi, Niloofar Habibi Khameneh, Keyvan Shahpoorzadeh, Atefe Saffar Shahroudi
https://creativecommons.org/licenses/by/4.0
 

Contact Us

The PKP Index is an initiative of the Public Knowledge Project.

For PKP Publishing Services please use the PKP|PS contact form.

For support with PKP software we encourage users to consult our wiki for documentation and search our support forums.

For any other correspondence feel free to contact us using the PKP contact form.

Find Us

Twitter

Copyright © 2015-2018 Simon Fraser University Library