Study of method of electrical resistance for evaluating the soil nailing integrity

Revista de Engenharia Civil IMED

View Publication Info
 
 
Field Value
 
Title Study of method of electrical resistance for evaluating the soil nailing integrity
Estudo do método da resistência elétrica para avaliação da integridade de solo grampeado
 
Creator Mikos, Ana Paula
Teixeira, Sidnei Helder Cardoso
 
Subject
Soil nailing; Non-destructive methods; Electrical resistance
Geotecnia, contenções
Solo grampeado, métodos não destrutivos, resistência elétrica
 
Description The slope improvement works with soil nailing are widely used along highways for stabilization of slope and landfill slopes. These structures differ from others, such as gravity walls or gabion meshes, because they have steel bars buried in the soil and surrounded by grouting. The major problem in soil nailing is the incomplete grouting along the hole, which can affect the performance of the structure. Moreover, soil nailing structures are buried, hence the most affordable inspection is visual, which makes more difficult to define the length and integrity of the elements. To improve the analyses and overcome the limitations, non destructive methods are used to evaluate all the elements of the retaining without disturbing the structure. The electrical resistance method can be used in the integrity evaluation of soil nailing. The methodology consists in compare the electric resistance between adjacent bars, which may conduct to different results, indicating executive failures or bar of different sizes. This paper aims to perform preliminary tests on a slope, before the construction of soil nailing, in order to understand the technique’s operation and to evaluate the influence of the electrical parameters of the soil. It was possible to notice that the evaluated slope presents lateral variation in electric resistance. Therefore, considering a future soil nailing there, it will be important to take into account the heterogeneity of the soil in results of electrical resistance.
As obras de melhoria de taludes com solo grampeado são amplamente utilizadas ao longo de rodovias para estabilização de taludes de cortes e aterro. Tal estrutura se diferencia das demais, como muro de gravidade e gabião, por apresentar barras de aço enterradas no solo, envoltas por calda de cimento. O principal problema que ocorre em solo grampeado é a falha no preenchimento com calda de cimento ao longo do furo, o que pode afetar no desempenho da contenção. Como são elementos enterrados, a inspeção é limitada ao campo visual, o que impossibilita definir o comprimento e a integridade dos elementos. Para aprimorar a análise e superar as limitações, os métodos não destrutivos são utilizados para avaliar todos os grampos da contenção sem afetar a estrutura. Dentre eles, o método da resistência elétrica, pode ser utilizado na avaliação da integridade de solo grampeado. A metodologia consiste em comparar a resistência elétrica entre os grampos próximos, e valores diferentes podem indicar falhas executivas ou barras de diferentes tamanhos. O objetivo do presente artigo foi realizar ensaios preliminares em um talude, anterior à construção do solo grampeado, de modo a entender o funcionamento da técnica e avaliar a influência dos parâmetros elétricos do solo. Foi possível perceber que o talude avaliado apresenta variação lateral da resistência elétrica. Portanto, uma futura contenção no local, deve-se atentar à importância da heterogeneidade do solo nos resultados de resistência elétrica.
 
Publisher Complexo de Ensino Superior Meridional S.A.
 
Contributor
Universidade Federal do Paraná
CAPES
Fundação Araucária
 
Date 2018-07-01
 
Type info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

 
Format application/pdf
text/html
 
Identifier https://seer.imed.edu.br/index.php/revistaec/article/view/2423
10.18256/2358-6508.2018.v5i1.2423
 
Source Revista de Engenharia Civil IMED; v. 5, n. 1 (2018): Jan.-Jun.; 121-139
2358-6508
2358-6508
10.18256/2358-6508.2018.v5i1
 
Language por
 
Relation https://seer.imed.edu.br/index.php/revistaec/article/view/2423/1893
https://seer.imed.edu.br/index.php/revistaec/article/view/2423/1894
/*ref*/ABU-HASSANEIN, Z. S., BENSON, C. H., BLOTZ, L. R. Eletrical Resistivity of Compacted Clays. Journal of Geotechnical Engineereing, v. 122, n. 5, p. 397-406, 1996.
/*ref*/ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15749. Medição de resistência de aterramento e de potenciais na superfície do solo em sistemas de aterramento. Rio de Janeiro, 2009.
/*ref*/BOSZCZOWSKI, R. B. Avaliação de propriedades mecânicas e hidráulicas de um perfil de alteração de granito-gnaisse de Curitiba, PR. Tese de Doutorado. Pontifícia Universidade Católica do Rio de Janeiro. Rio de Janeiro: 2008.
/*ref*/BRAGA, A. C. O. Métodos da eletrorresistividade e polarização induzida aplicados nos estudos da captação e contaminação de águas subterrâneas: uma abordagem metodológica e prática. Dissertação de Mestrado. Universidade Estadual Paulista. Rio Claro, 2006.
/*ref*/CAMPANELLA, R. G.; WEEMEES, I. Development and use of an electrical resistivity cone for groundwater contamination studies. Civil Engineering Department. The University of British Columbia, Vancouver, B.C., Canada: 1990.
/*ref*/CHEUNG, W. M. Non-destructive tests for determining the lengths of installed steel soil nails. Geo Report 133. Geotechnical engineering office. Civil engineering department. Hong Kong, 2003.
/*ref*/CHEUNG, W. M.; LO, D. O. K. Interim report on non-destructive tests for checking the integrity of cement grout sleeve of installed soil nails. Geo Report 176. Geotechnical engineering office. Civil engineering and development department. Hong Kong: 2005.
/*ref*/CHIOSSI, N. J. Geologia Aplicada a Engenharia. Grêmio Politécnico. São Paulo, 1979.
/*ref*/GOWERS, K. R.; MILLARD, S. G. Measurement of concrete resistivity for assessment of corrosion severity of steel using Wenner technique. ACI Materials Journal, n. 96-M66, 1999.
/*ref*/GUIMARÃES NETO, J.M. Estudo de Metodologias Adotadas no Cálculo de Estruturas de Contenção com Solos Grampeados (Soil Nailing) com a Apresentação de um Estudo de Caso. Trabalho Final de Curso, Feira de Santana, BA, Bahia: 2008.
/*ref*/JAYAWICKRAMA, P. W.; TINKEY, Y.; GONG, J.; TURNER, J. Non-Destructive Evaluation of Installed Soil Nails. Report No. FHWA/TX 07–258. Texas: 2007.
/*ref*/LAZARTE, C. A.; ROBINSON, H.; GÓMEZ, J. E.; BAXTER, A.; CADDEN, A.; BERG, R. Soil Nail Walls Reference Manual. Report No. FHWA-NHI-14-007. 2015.
/*ref*/LEE, C. F.; ARUP, O. Review of Use of Non-Destructive Testing in Quality Control in Soil Nailing Works. GEO Report 219 Geotechnical engineering office. Civil engineering and development department. Hong Kong: 2007.
/*ref*/LEITE, C. M. Técnicas de Aterramentos Elétricos. 2ª Edição. Officina de Mydia. São Paulo, 1996.
/*ref*/MAMEDE FILHO, J. Instalações Elétricas Industriais. Editora LTC. 7ª Edição, 2007.
/*ref*/MEDEIROS JR., R. A.; LIMA, M. G. Electrical resistivity of unsaturated concrete using different types of cement. Construction and Building Materials. Novembro, 2016.
/*ref*/MIKOS, A. P. Caracterização geotécnica de campo experimental para avaliação do método não destrutivo da resistência elétrica em solo grampeado. Dissertação de mestrado, Universidade Federal do Paraná. Curitiba, 2017.
/*ref*/PITTA, C. A.; SOUZA, G. J. T.; ZIRLIS, A. C.; FERREIRA, J. F. C. Quanto tempo durarão as cortinas atirantadas executadas a partir da década de 70? 30 anos? XIII COBRAMSEG. 2006.
/*ref*/PITTA, C. A.; SOUZA, G. J. T.; ZIRLIS, A. C. Alguns detalhes da pratica de execução de solo grampeado. In: VI Conferencia Brasileira de Encostas–COBRAE. 2013.
/*ref*/ORTIGÃO, J. A. R., PALMEIRA, E. M., ZIRLIS, A. Experience with soil mailing in Brazil: 1970-1994. Proceedings of the Institution of Civil Engineers, Geotechnical Engineering. London: 1995.
/*ref*/SANTOS, G.A.F. Soluções de Pregagem para a Estabilização de Taludes: uma Contribuição para o seu Dimensionamento, Dissertação de Mestrado, Programa de Pós-Graduação em Geotecnia, Departamento de Engenharia Civil, Faculdade de Ciências e Tecnologia Universidade Nova de Lisboa. 2014.
/*ref*/SIGA Jr, O; BASEI, M. A. S.; REIS NETO, J. M.; MARCHIAVELLI, A.; HARARA, O. M. O Complexo Atuba: um cinturão Paleoproterozóico intensamente retrabalhado no Neoproterozóico. Boletim do Instituto de Geociências, Série Científica, USP, v. 26, p. 69-98, 1995.
/*ref*/SOUZA, G. J. T.; PITTA, C. A.; ZIRLIS, A. C. Solo grampeado – aspectos executivos do chumbador. IV COBRAE – Conferência Brasileira sobre estabilidade de encostas. Salvador: 2005.
/*ref*/SOUZA, K. T.; MOURA, R. F.; CINTRA, G. Estudo de alternativas para a construção de malhas de aterramento num solo com alta resistividade elétrica. In: II Congresso de Pesquisa e Inovação da Rede Norte Nordeste de Educação Tecnológica, 2007.
 
Rights Direitos autorais 2018 Ana Paula Mikos, Sidnei Helder Cardoso Teixeira
http://creativecommons.org/licenses/by/4.0
 

Contact Us

The PKP Index is an initiative of the Public Knowledge Project.

For PKP Publishing Services please use the PKP|PS contact form.

For support with PKP software we encourage users to consult our wiki for documentation and search our support forums.

For any other correspondence feel free to contact us using the PKP contact form.

Find Us

Twitter

Copyright © 2015-2018 Simon Fraser University Library