The Impact of Changes in Exhaust Temperature on the Power Output and Heat Rate of a Gas Turbine with a Capacity of 238 MW
INTEK: Jurnal Penelitian
View Publication InfoField | Value | |
Title |
The Impact of Changes in Exhaust Temperature on the Power Output and Heat Rate of a Gas Turbine with a Capacity of 238 MW
|
|
Creator |
Parapa', Hendra Budiono Putra
|
|
Subject |
Exhaust Temperature; Power Output; Heat Rate
|
|
Description |
The exhaust temperature parameter is one of the parameters that need to be considered in maintaining the performance of the gas turbine. The purpose of this study is to analyze the effect of changes in exhaust temperature on power output and heat rate. The data used is the actual design data of the M701 gas turbine. This data is used in building the model using the GateCycle software. The modeling simulation results are then validated using the actual design data. To see the impact of changes in exhaust temperature, data from the latest gas turbine performance results are used. This study concludes that changes in exhaust temperature parameters of 1OC have an impact on changes in power output of 0.273% and heat rate of 0.047%.
|
|
Publisher |
Politeknik Negeri Ujung Pandang
|
|
Contributor |
PT. PLN (Persero) UPDL Makassar
|
|
Date |
2021-10-13
|
|
Type |
info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion — — |
|
Format |
application/pdf
|
|
Identifier |
http://jurnal.poliupg.ac.id/index.php/Intek/article/view/2892
10.31963/intek.v8i2.2892 |
|
Source |
INTEK: Jurnal Penelitian; Vol 8, No 2 (2021): October 2021; 96-100
INTEK: Jurnal Penelitian; Vol 8, No 2 (2021): October 2021; 96-100 2615-5427 2339-0700 10.31963/intek.v8i2 |
|
Language |
eng
|
|
Relation |
http://jurnal.poliupg.ac.id/index.php/Intek/article/view/2892/pdf
|
|
Rights |
Copyright (c) 2021 Hendra Budiono Putra Parapa'
http://creativecommons.org/licenses/by/4.0 |
|